Description

Problem:

Connect best quality MB Star C3 diagnostic system with 2000 Benz Correceria c200 203, no indicator light on and no communication between multiplexer and equipment. The system window pops out error message: “Detection of multiplexer initialization failed”
MB Star C3 Detection of multiplexer initialization failed 

Possible reasons:

1) Detection of the multiplexer and element disconnect between switch socket
2) Detection of the disconnect between multiplexer and equipment
3) The voltage of power supply switch (terminal 30 or 31) is not correct
4) In order to use SDCONECT, try to link through KI tools

Solution:

1) Check the connection between multiplexer and equipment. If there is well connection between device and vehicle, the indicator should flash after start the engine.
2) Try to test on another vehicle.
3) Change another connection cable. Mbstarshop provided good quality RS232 to RS485 Cable for MB Star C3.
Write a Review
* Rating:
    Please select rating stars.
* Your First & Last Name:
* Your E-Mail Address:
* Review Detail:
*Verification Code:
      3300    No right? Get a new Verification Code
 
Tell us what you think about this item and share your opinions with other people. Please make sure your review focuses only on this item. All reviews are moderated and will be reviewed within two business days. Inappropriate reviews will not be posted.
After-sales questions and issues: Contact our Customer Service Department. (A customer representative will get back to you).
Please Sign In first if you want to later edit or manage reviews uploaded by yourself.
Bookmark It